TY - JOUR
T1 - Validity of real-time data generated by a wearable microtechnology device
AU - Weaving, D.
AU - Whitehead, S.
AU - Till, K.
AU - Jones, Ben
N1 - Publisher Copyright:
© 2017 National Strength and Conditioning Association.
PY - 2017/10/31
Y1 - 2017/10/31
N2 - The purpose of this study was to investigate the validity of global positioning system (GPS) and micro-electricalmechanical- system (MEMS) data generated in real time through a dedicated receiver. Postsession data acted as the criterion as it is used to plan the volume and intensity of future training and is downloaded directly from the device. Twenty-five professional rugby league players completed 2 training sessions wearing an MEMS device (Catapult S5, firmware version: 5.27). During sessions, real-time data were collected through the manufacturer receiver and dedicated software (Openfield v1.14), which was positioned outdoors at the same location for every session. The GPS variables included total-, low- (0-3 m·s
-1), moderate- (3.1-5 m·s
-1), high- (5.1-7 m·s
-1), and very high-speed (>7.1 m·s
-1) distances. Micro-electrical-mechanical-system data included total session PlayerLoad. When compared to postsession data, mean bias for total-, low-, moderate-, high-, and very high-speed distances were all trivial, with the typical error of the estimate (TEE) small, small, trivial, trivial and small, respectively. Pearson correlation coefficients for total-, low-, moderate-, high- and very-high-speed distances were nearly perfect, nearly perfect, perfect, perfect, and nearly perfect, respectively. For PlayerLoad, mean bias was trivial, whereas TEE was moderate and correlation nearly perfect. Practitioners should be confident that when interpreting real-time speed-derived metrics, the data generated in real-time are comparable with those downloaded directly from the device postsession. However, practitioners should refrain from interpreting accelerometer-derived data (i.e., PlayerLoad) or acknowledge the moderate error associated with this realtime measure.
AB - The purpose of this study was to investigate the validity of global positioning system (GPS) and micro-electricalmechanical- system (MEMS) data generated in real time through a dedicated receiver. Postsession data acted as the criterion as it is used to plan the volume and intensity of future training and is downloaded directly from the device. Twenty-five professional rugby league players completed 2 training sessions wearing an MEMS device (Catapult S5, firmware version: 5.27). During sessions, real-time data were collected through the manufacturer receiver and dedicated software (Openfield v1.14), which was positioned outdoors at the same location for every session. The GPS variables included total-, low- (0-3 m·s
-1), moderate- (3.1-5 m·s
-1), high- (5.1-7 m·s
-1), and very high-speed (>7.1 m·s
-1) distances. Micro-electrical-mechanical-system data included total session PlayerLoad. When compared to postsession data, mean bias for total-, low-, moderate-, high-, and very high-speed distances were all trivial, with the typical error of the estimate (TEE) small, small, trivial, trivial and small, respectively. Pearson correlation coefficients for total-, low-, moderate-, high- and very-high-speed distances were nearly perfect, nearly perfect, perfect, perfect, and nearly perfect, respectively. For PlayerLoad, mean bias was trivial, whereas TEE was moderate and correlation nearly perfect. Practitioners should be confident that when interpreting real-time speed-derived metrics, the data generated in real-time are comparable with those downloaded directly from the device postsession. However, practitioners should refrain from interpreting accelerometer-derived data (i.e., PlayerLoad) or acknowledge the moderate error associated with this realtime measure.
KW - Accelerometers
KW - Global positioning systems
KW - PlayerLoad
KW - Training load
UR - http://www.scopus.com/inward/record.url?eid=2-s2.0-85045031612&partnerID=MN8TOARS
UR - http://www.scopus.com/inward/record.url?scp=85045031612&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85045031612&partnerID=8YFLogxK
UR - https://www.mendeley.com/catalogue/0106575b-e5a0-365c-b075-8ba723fc68cf/
U2 - 10.1519/JSC.0000000000002127
DO - 10.1519/JSC.0000000000002127
M3 - Article (journal)
SN - 1064-8011
VL - 31
SP - 2876
EP - 2879
JO - Journal of Strength and Conditioning Research
JF - Journal of Strength and Conditioning Research
IS - 10
ER -